AO Smith Boiler GWGWO 300 User Manual

Commercial Gas Boilers  
MODELs  
gw/gwO-300  
thrOugh  
84% efficient, low-nox hot water supply boilers  
features  
gw/gwO-750  
A. O. Smith Genesis® boilers offer everything you could ask for in a non-condensing boiler.  
They provide the highest possible 84% thermal efficiency, outstanding venting flexibility,  
space-saving stackable design and a new, advanced Energy Management Control (EMC) system.  
Genesis models are available for installation indoors (GW Series) or outdoors (GWO Series).  
new eMc-5000 enerGy ManaGeMent control  
Patent pending  
Controls every electrical boiler function, including pump operation and main burner ignition,  
delivers precise temperature management, with 1º accuracy  
Display panel shows current operating status and fault readings in easy-to-understand  
English instead of confusing numeric codes  
Display also shows temperature setpoints, outlet temperature, current inlet/outlet  
differential ( T) and tank temperature  
Help screens assist in boiler setup and explain control options  
Included remote temperature sensor when mounted in the storage tank  
allows the tank temperature to be set and monitored at the boiler  
two-staGe Gas firinG systeM  
Twin gas valve firing system prevents short cycling and ensures  
smooth operation, saves fuel and extends boiler life  
Prevents short cycling when demand is low, delivers maximum output when  
demand is high  
low-nox operation  
Meets or exceeds Texas and California SCAQMD Rule 1146.2 air quality standards  
copper finneD-tube heat exchanGer  
Designed for maximum durability and serviceability  
Copper is lightweight for easier handling and immune to thermal shock  
Removable headers allow easy inspection of waterways  
space-saVinG DesiGn  
Smaller footprint versus other horizontal copper fin-tube boilers  
Optional stack rack allows one unit to be stacked on top of another, doubling output within  
the footprint of a single unit  
Meets ashrae/iesna 90.1-2004  
fiVe-year heat exchanGer liMiteD warranty  
For complete information, consult written warranty or contact A. O. Smith  
Revised November 2008  
PG 1 OF 4  
AOSDG25200  
Commercial Gas Boilers  
Gw series inDoor MoDels  
Gwo series outDoor MoDels  
DIMENSIONS IN INCHES  
(SEE DRAWINGS ABOVE)  
MODEL  
NUMBER  
BTU INPUT  
PER HOUR  
EXHAUST VENT  
AIR INLET  
WATER CONN.  
GAS PIPE  
WIDTH  
A
B
C
GW SERIES INDOOR MODELS  
GW-300  
GW-400  
GW-500  
GW-650  
GW-750  
300,000  
399,900  
500,000  
650,000  
750,000  
5
6
6
8
8
5
6
6
8
8
1-1/2  
3/4  
1
29-1/2  
35-3/4  
42  
14-13/16  
17-15/16  
21-1/16  
25-3/4  
9
9
9
9
9
12  
1-1/2  
14-3/4  
14-3/4  
14-3/4  
17-1/4  
2
2
2
1
1-1/4  
1-1/4  
51-3/8  
57-3/8  
28-7/8  
GWO SERIES OUTDOOR MODELS  
GW-300  
GW-400  
GW-500  
GW-650  
GW-750  
300,000  
400,900  
500,000  
650,000  
750,000  
-
-
-
-
-
-
-
-
-
-
1-1/2  
3/4  
1
-
-
-
-
-
49  
24-3/16  
-
1-1/2  
55-1/4  
61-1/2  
70-7/8  
77-1/8  
24-3/16  
-
2
2
2
1
24-3/16  
-
1-1/4  
1-1/4  
-
-
27-11/16  
27-11/16  
Revised November 2008  
PG 2 OF 4  
AOSDG25200  
Commercial Gas Boilers  
other Genesis® features  
Genesis® VentinG Versatility  
Direct-VentinG  
factory-installeD circulatinG puMp  
Pre-wired, integrally controlled by EMC-5000 control  
Adjustable pump time delay allows removal of usable residual  
heat during stand-by cycle, virtually eliminating stand-by heat loss  
asMe pressure relief ValVe 125#  
factory installeD flow switch  
alternate therMostat terMinals (24V)  
Manual reset hiGh liMit  
blocKeD flue switch  
blocKeD inlet switch  
air proVinG switch  
Genesis® options  
CSD-1 CODE  
NEW YORK CODE  
siDewall VentinG  
conVentional VentinG  
CALIFORNIA CODE  
ALARM BELL  
ALL-BRONZE CIRCULATING PUMP  
HARD WATER PUMP  
BRONZE HEADERS  
STACK RACK  
LOW WATER CUT-OFF  
EXTENDED VENTING KIT  
SEQUENCING CONTROL PANEL (FOR 2-8 BOILERS)  
COMBUSTIBLE FLOOR SHIELD  
DRY CONTACTS FOR ANY BOILER FAILURE  
CUPRO-NICKEL HEAT EXCHANGER  
CSA CERTIFIED VENT KIT  
For the most current Genesis venting distances/information,  
consult the Genesis Product Manual, available through your local  
RECOVERy — GALLONS PER HOUR AT °f TEMPERATURE RISE  
MODEL  
NUMBER  
BTU INPUT  
PER HOUR  
40°  
50°  
609  
60°  
507  
70°  
435  
580  
725  
942  
1087  
80°  
380  
507  
634  
824  
951  
90°  
338  
451  
564  
733  
845  
100°  
304  
406  
507  
659  
761  
110°  
277  
369  
461  
600  
692  
120°  
254  
338  
423  
600  
634  
130°  
234  
312  
390  
507  
585  
140°  
217  
290  
362  
471  
544  
GW/GWO-300  
GW/GWO-400  
GW/GWO-500  
GW/GWO-650  
GW/GWO-750  
300,000  
399,900  
500,000  
650,000  
750,000  
761  
1014  
1268  
1649  
1902  
811  
676  
1015  
1319  
1522  
845  
1099  
1268  
Gas Supply Pressure: 13.8” W.C. maximum natural and propane; 4.5” W.C. minimum natural; 11.0” W.C. minimum propane.  
Genesis boilers are approved for installation on noncombustible flooring in an alcove with minimum clearance to combustibles of:  
3 inches sides, and back; 3 inches top, front alcove; 6 inches vent.  
For installation on combustible flooring use the optional Combustible Floor Kit.  
Genesis boilers must be connected to a single phase dedicated line source that is: 120 volts, 60 hertz and 20 amps.  
Revised November 2008  
PG 3 OF 4  
AOSDG25200  
Commercial Gas Boilers  
suGGesteD specification  
The hot water supply boiler(s) shall be an A. O. Smith Genesis® Model GW ___________________ having an input rating of __________________ BTU/hr.  
and capable of supplying no less than _________________GPH at a 100ºF temperature rise when fired with Natural/Propane gas. The boiler shall bear  
the ASME “H” stamp and shall be National Board registered for 160 PSI working pressure. The boiler shall be test certified at 84% thermal efficiency  
by CSA per ANSI Z21.13/CSA 4.9 Harmonized Standard Latest Addenda. The boiler’s copper fin tube heat exchanger shall be a horizontal, single row,  
two pass design. The solid copper tubes shall have integral extruded copper fins spaced at “7” fins per inch, and be rolled into heavy steel tube sheets.  
High temperature silicone “O” rings shall provide a watertight seal between each tube and the ASME code Bronze/Cast Iron headers. Headers must  
be field removable to allow complete inspection of all waterways. Non-removable headers, with tubes rolled directly into the headers, shall not be  
acceptable. The low mass, low water volume heat exchanger shall be explosion-proof and immune to thermal shock.  
The combustion chamber shall be fully lined with high temperature ceramic fiber insulation, rated to 2,300°F. The jacket panels shall be coated with  
a baked-on powder-coat finish, suitable for outdoor service. The jacket shall be of tight construction, and weather- and water-resistant.  
The hot water supply boiler(s) shall be supplied with a factory supplied, sized and wired boiler-circulating pump.  
The boiler shall employ a fan induced premixed multi-burner system firing into a pressurized combustion chamber. Atmospheric or power burners will  
not be acceptable. Only stainless steel/titanium alloy burners will be acceptable. All boiler functions shall be controlled, operated, and monitored by  
a microprocessor-based control. The microprocessor shall control the boiler temperature and be accurate to within plus or minus 1°F. The hot surface  
ignition system shall employ a separate flame sensor for maximum reliability.  
The boiler shall be supplied with a remote tank thermistor for sensing and controlling the hot water storage tank temperature up to 1,000 feet away.  
Provisions for connecting a remote thermistor, alarm bell, pump, and alternate temperature controller must be provided.  
Factory mounted and wired flow, blower prover, and blocked flue switches shall be provided. The gas train shall meet or exceed the requirements  
of ANSI Z21.13 and include gas pressure regulator, manual gas cock, redundant safety gas valve, operating control valve, and plugged pressure test  
tapings. The ASME rated pressure relief shall be factory installed.  
The boiler shall be certified for direct horizontal through-the-wall venting, or direct vertical venting; in addition to sidewall or conventional vertical  
venting. The boiler must be field convertible from top mounted venting to rear mounted venting. The boiler shall be capable of horizontal sidewall  
or direct venting up to 35 equivalent feet without the aid of any optional sidewalll vent fans or blowers.  
for technical information and automated fax service, call 800-527-1953. a.o. smith corporation reserves the right to make product changes or improvements without prior notice.  
Revised November 2008  
PG 4 OF 4  
AOSDG25200  