AO Smith Water Heater AOSRG45700 User Manual

Residential Gas Water Heaters  
DIRECT-VENT  
ProMax® Direct-Vent Features  
DIRECT-VENT DESIGN  
One-pipe, dual-channel closed-combustion system draws all make-up air  
from outside the home, eliminating problems caused by insufficient indoor  
ventilation, and is FVIR compliant  
Horizontal air intake and venting on all models up to 80 inches from  
outside wall, with no electrical power needed.  
A. O. SMITH DYNACLEAN™ DIFFUSER DIP TUBE  
Helps reduce lime and sediment buildup, maximizes hot water output.  
Made from long-lasting PEX cross-link polymer.  
GREEN CHOICE™ GAS BURNER  
Patented “eco-friendly” design reduces NOx emissions up to 33% and  
complies with Southern California and Texas requirements.  
PUSH BUTTON PIEZO IGNITER  
Makes lighting pilot fast and easy with one hand push button spark  
ignition.  
HEAT TRAP NIPPLES Factory installed.  
DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE  
A. O. SMITH PERMAGLAS® GLASS COATING  
Protects steel tank from rust.  
FACTORY-INSTALLED TEMPERATURE & PRESSURE (T&P)  
RELIEF VALVE  
6-YEAR LIMITED TANK & PARTS WARRANTY  
For complete information, consult written warranty or A. O. Smith Water  
Products Company.  
CODE COMPLIANCE: UBC, CEC, SBCC, CABO, HUD, BOCA  
NATIONAL CODES, ASHRAE/IES 90.1-1999 AND 2004 NAECA  
DESIGN-CERTIFIED BY CSA INTERNATIONAL  
According to ANS Z21.10.1 standards governing storage-type water  
heaters.  
Page 1 of 2  
Revised April 2008  
AOSRG45700  
Residential Gas Water Heaters  
DIRECT-VENT  
FIRST  
HOUR  
RECOVERY  
90ºF RISE  
GALLONS  
PER HOUR  
APPROX.  
SHIPPING  
DIMENSIONS IN INCHES  
BTU  
INPUT  
MODEL  
ENERGY GAL.  
VENT  
NUMBER RATING FACTOR CAP.  
GALLONS  
OUTLET* WEIGHT  
(LBS)  
A
B
C
D
E
F
PER HOUR  
GDV-40  
GDV-50  
73  
87  
.62  
.60  
40  
50  
38,000  
42,000  
41  
45  
68  
76  
54-3/4 22-1/4  
63-3/4 22-1/4  
16  
16  
12-1/4 45-1/4 Co-Axial  
12-1/4 54 Co-Axial  
167  
185  
GDVT-50  
GDV-75  
88  
.59  
.59  
50  
75  
50,000  
55,000  
55  
60  
76  
76  
64-3/4 22-1/4 16-1/4 12-1/2 55-1/2 Co-Axial  
65-3/4 26-1/4 16-1/4 12-1/2 55-1/2 Co-Axial  
187  
310  
131  
Recovery capacities based on actual performance tests.  
* Dual-channel system has 3˝ vent pipe inside 6˝ air intake pipe, for the 40 & 50 gallon models.  
The 75 gallon model uses a 4” x 7” co-axial pipe.  
All Models Have 2” Foam Cavity.  
40 & 50 gal.  
25-1/4  
Water connection 3/4” male all models.  
75 gallon water connections are 12” on center.  
75 gal.  
29-1/2  
Important! Vent Installation and Termination Requirements  
42°  
47°  
n Maximum horizontal vent distance is 80” to outside of exterior wall.  
n Minimum horizontal vent distance is 17” to outside of exterior wall.  
n Vent pipes may be trimmed (cut) for short vent installations.  
n For vent installation less than 30” the vent restrictor is required.  
Place restrictor over the flue outlet on heater before installing the outlet vent  
pipe to the heater.  
n Recommended installation height for the heater vent pipe should be  
68” for 40 gallon models and 76” for the 50-gallon and 75-gallon  
models (vent height).  
TOP  
MIN VENT  
17  
MAX VENT  
80  
n Offset Vent Arrangement  
6” DIA. on 40 & 50 Gal. Models  
1. When replacing an existing direct vent model,  
the new vent pipe may drop from the minimum  
vent height as much as 7 1/4” to exit through the  
existing vent opening in the exterior wall.  
7” DIA. o  
n 7  
5
Gal. Models  
75 gal. vent  
termination  
cap is not  
interchangeable  
with vent cap  
on 40 & 50 gal.  
models  
2. Vent may have one horizontal 90 degree turn before  
exiting through exterior wall (Do not combine both  
offset vent arrangements in one installation) (See  
examples in the installation manual)  
n High Rise Vent Arrangement  
EXTERIOR  
WALL  
3. When vent termination is more than 80” above the  
base of the heater. The horizontal vent run must be  
a minimum of 22” from the center of the heater to  
the outside exterior wall surface. (See example in the  
C
installation manual)  
n Vent termination clearance hole through the exterior  
wall should be approximately 7” diameter.  
A
B
n Snow accumulation and drifting should be considered  
when locating the termination.  
F
n An optional wire grill vent cap protector is available  
through the parts department. Part number 9006627.  
n See the installation manual for complete installation  
and venting requirements.  
D
E
FRONT  
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.  
Page 2 of 2  
Revised April 2008  
AOSRG45700  

AO Smith Boiler LBLW 500 User Manual
AO Smith Water Heater EQH 200 G User Manual
AO Smith Water Heater GDVH 40Q User Manual
AO Smith Water Heater Series 201 User Manual
AO Smith Water Heater Water Heater User Manual