AO Smith Water Heater AOSRG46600 User Guide

Residential Heating  
CIRCULATING LOOP HEAT EXCHANGERS  
The ProMax® XL circulating loop heat exchanger is designed specifically for  
installation with A.O. Smith ProMax® SL (Side Loop) gas water heaters.  
The combination of a ProMax SL water heater and ProMax XL heat exchanger  
provides domestic hot water, and an isolated source of hot water for radiant  
floor heating, hydronic air handlers and other closed loop applications.  
OUTPUT OPTIONS  
â–  28,000 BTU (RXLD-28 and RXLS-28)  
â–  52,000 BTU (RXLD-52 and RXLS-52)  
COMPACT, EFFICIENT, BRAZED PLATE HEAT EXCHANGER  
â–  UP TO 60% smaller than traditional shell & tube and coaxial heat exchangers  
SINGLE OR DOUBLE-WALL DESIGN  
â–  Double-wall construction for applications requiring double isolation between fluid streams  
AUXILIARY CONNECTIONS EXPAND OPTIONS  
â–  Plugged connections can be used as installation points for thermowells, a drain or for flushing  
heat exchanger  
â–  Connections located on front of heat exchanger, common to primary side of heat exchanger  
115V/60Hz PUMP  
â–  Control relay (24 volt coil) located inside wiring junction box  
PROMAX SL GAS WATER HEATER OPTIONS  
â–  Standard Vent  
â–  Direct Vent  
â–  Power Vent  
â–  Power Direct-Vent  
STANDARDS  
â–  All components UL Listed  
1-YEAR LIMITED WARRANTY  
â–  For complete information, consult written warranty or contact A.O. Smith Water Heaters  
Page 1 of 2  
Revised July 2008  
AOSRG46600  
ARGSS00307  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Residential Heating  
CIRCULATING LOOP HEAT EXCHANGERS  
COIL & AIR HANDLER APPLICATION - HEAT EXCHANGER SELECTION TABLE  
1400F SOURCE (TANK)  
1500F SOURCE (TANK)  
1600F SOURCE (TANK)  
BTUH  
GPM  
GPM  
BTUH  
GPM  
PD (FT.)  
BTUH  
PD (FT.)  
PD (FT.)  
MODEL  
28,000  
52,000  
2.8  
5.2  
1.0  
0.9  
3.7  
0.5  
DOUBLE WALL  
RXLD-28  
RXLD-52  
30,000  
55,000  
3.0  
5.5  
1.1  
1.1  
55,000  
79,000  
5.5  
2.3  
HEAT EXCHANGER  
SINGLE WALL  
2.8  
5.2  
1.1  
1.7  
4.3  
8.5  
RXLS-28  
RXLS-52  
0.7  
1.3  
36,000  
60,000  
68,000  
95,000  
6.8  
9.6  
28,000  
52,000  
3.6  
6.0  
HEAT EXCHANGER  
RADIANT FLOOR APPLICATION - HEAT EXCHANGER SELECTION TABLE  
1400F SOURCE (TANK)  
1600F SOURCE (TANK)  
1500F SOURCE (TANK)  
BTUH  
GPM  
PD (FT.)  
BTUH  
GPM  
PD (FT.)  
BTUH  
GPM  
PD (FT.)  
MODEL  
DOUBLE WALL  
RXLD-28  
RXLD-52  
28,000  
52,000  
48,000  
82,000  
4.9  
8.3  
3.0  
2.4  
65,000  
5.3  
4.1  
1.0  
0.9  
6.5  
2.8  
5.2  
110,000  
11.1  
HEAT EXCHANGER  
0.7  
1.3  
50,000  
84,000  
98,000  
8.9  
6.2  
SINGLE WALL  
28,000  
52,000  
5.0  
8.4  
2.3  
3.6  
9.8  
RXLS-28  
RXLS-52  
2.8  
5.2  
HEAT EXCHANGER  
115,000  
11.6  
PROMAX SL WATER HEATER  
CROSS-REFERENCE  
HEAT EXCHANGER PRESSURE DROP  
For Secondary Loop Flow Calculations.  
PROMAX SL  
WATER HEATER  
MODELS  
GCVH-40L  
OUTPUT  
29,600  
38,000  
50,050  
49,400  
57,000  
STANDARD GCVT-50L  
VENT  
GCVX-50L  
GCV-65L  
FCG-75L  
GDV-40L  
GDVT-50L  
GDV-75L  
30,780  
40,500  
44,550  
DIRECT  
VENT  
GPVT-40L  
GPVT-50L  
GPVX-50L  
GPS-75L  
39,000  
39,500  
49,400  
64,000  
30,400  
47,450  
53,200  
POWER  
VENT  
GPD-40L  
GPDX-50L  
GPD-75L  
POWER  
DIRECT  
VENT  
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.  