AO Smith Water Heater ATI 705N User Manual

A. O. Smith On-Demand  
Gas Water Heaters  
Each A. O. Smith on-demand water heater is designed for a  
specific application. Consult your sales representative or contact  
A. O. Smith for specifications and recommendations on which  
model is right for specific requirements.  
INNOVATION ON DEMAND  
A. O. Smith’s complete line of tankless gas water heaters  
Model Specifications  
BTU Input  
Approximate  
Shipping  
Weight (lbs)  
Model  
Number  
Natural / Propane  
Hot Water Output (GPM)  
45º F Rise  
Minimum  
Maximum  
Maximum  
77º F Rise  
INDOOR MODELS  
ATI-305N  
15,000  
15,000  
19,000  
19,000  
199,000/190,000  
199,000/190,000  
237,000  
5.3  
8.5  
9.8  
9.8  
5.3  
7.4/7.1  
8.8  
4.2  
4.2  
5.1  
5.1  
50  
50  
55  
55  
ATI-505N  
ATI-705N  
ATI-705AN*  
237,000  
8.8  
OUTDOOR MODELS  
ATO-305N  
ATO-505N  
ATO-705N  
ATO-705AN*  
15,000  
15,000  
19,000  
19,000  
199,000  
199,000  
237,000  
237,000  
5.3  
8.5  
9.8  
9.8  
5.3  
7.3  
8.7  
8.7  
4.2  
4.2  
5.1  
5.1  
50  
50  
55  
55  
* 705A models are ASME Certified.  
For propane, change “N” to “P” in model number (ATI-305P).  
500 Tennessee Waltz Parkway  
Ashland City, TN 37015  
AMGBROO107 ©2007 A. O. Smith Corporation  
te er08R  
A. O. Smith reserves the right to make product changes or improvements at any time without notice.  
Printed in U.S.A  
S
e
p
m
b
20  
In Use Indicator Light  
Indicates hot water is being supplied  
(a tap is open)  
Remote  
Temperature Display  
Priority Indicator  
Indicates that this controller is  
setting the temperature  
A. O. Smith On-Demand  
Gas Water Heaters  
Shows the temp setting  
Controller  
All models come with a  
Remote controller that  
can set the temperature  
within a specific range.  
Error Codes  
When a fault is detected an error code  
flashes at the temperature setting  
Priority Button  
Priority can be changed to another  
controller if desired  
Endless Hot Water. Endless Innovation.  
Trust the innovation leader to give  
you more choices in on-demand water  
heating. A. O. Smith’s comprehensive  
line supplies endless hot water when  
you ask for it...with high efficiency that  
saves money on both residential and  
commercial applications.  
Thermostat  
On/Off Button  
Increases/decreases temp setting  
Will turn the water heater on/off  
Model Selection Guide  
Ground water  
temperature factor.  
Average Ground Water Temperatures  
The temperature of incoming  
ground water (cold water inlet  
temperature)  
throughout the U.S. and also  
fluctuates with change of season.  
The temperature of water as it  
enters the water heater will  
varies  
greatly  
determine  
the  
amount  
of  
“temperature rise” required to  
achieve the desired hot water  
outlet temperature (120°F is  
recommended).  
Product Features:  
The best way to measure your  
incoming ground water temperature  
is to use a thermometer to measure  
cold water temperature during the  
coldest season of the year. To  
simplify the process, use this map to  
determine whether your installation  
location is in the Southern Zone,  
Central Zone or Northern Zone.  
Innovative Technology  
Energy Efficiency  
Commercial  
SOUTHERN ZONE  
CENTRAL ZONE  
NORTHERN ZONE  
Indoor and outdoor installation options  
Up to 84% thermal efficiency,  
Application Features:  
Average Ground Water  
Average Ground Water  
Average Ground Water  
providing significant energy  
cost savings  
Continuous hot water on demand  
Temperature: 62°F to 77°F  
Temperature: 52°F to 61°F  
Temperature: 37°F to 51°F  
(up to 9.8 GPM)  
• ASME Certified  
Whole house water heating solution  
• Hot water capacity of 0.6 – 9.8 GPM  
Sleek Design  
Direct electronic ignition –  
• Min. – Max. input: 19,000 – 237,000 BTU  
Smooth pleasant lines and  
no pilot light  
Peak hot water demand.  
rounded corners  
Ground Water Temperature Zone  
Appliances or fixtures  
in simultaneous use  
during peak demand  
• Max. temperature: 185°F with  
Commercial Controller  
On-board diagnostics and  
The next step is to determine how  
much hot water will be required  
during the busiest usage period  
(“peak demand”). To use the chart,  
consider all appliances and fixtures  
that use hot water including  
lavatory faucets, kitchen faucets,  
washing machines, dishwashers,  
showers and bathtubs. Be sure to  
determine how many appliances  
and fixtures will be used at the  
same time (“peak demand”).  
Matching pipe cover available  
Southern Zone  
Central Zone  
305 or 505  
305 or 505  
(2) 505 or 705  
(2) 505  
Northern Zone  
305 or 505  
305 or 505  
(2) 505  
safety monitoring  
for finished appearance  
• Ideal for small restaurants, multifamily  
housing, hair salons and spas,  
laundromats, car washes and other  
limited commercial needs  
1
305 or 505  
305 or 505  
505 or 705  
(2) 505  
Interior sealed combustion  
(does not use interior combustion air)  
2
Applicable for residential hydronic  
3
heating applications  
4
5
(2) 505  
(2) 505  
(2) 705  
(2) 705  
Excellent Performance  
6 or more  
Multi-system  
Multi-system  
Multi-system  
12-year limited warranty on  
heat exchanger, 5-year warranty  
on all parts  
*Note: This selection guide is based on 120°F outlet water temperature.  
Can be installed outdoors, saving  
valuable indoor square footage  

AO Smith Boiler HW 300 THRU HW 610 User Manual
AO Smith Water Heater AOSRE50400 User Manual
AO Smith Water Heater DEL 40 User Manual
AO Smith Water Heater ESTT 30 User Manual
AO Smith Water Heater FMD 30 User Manual