AO Smith Water Heater BFC 28 User Manual

Cyclone BFC  
Condensing Glass-Lined  
Water Heater  
BFC - 28/30/50/60/80/100  
Fully room-sealed condensing high-efficiency water heater (95%gross)  
• Flexible flue options (maximum length 115 m) allows installation  
almost anywhere • ThermoControl for easy flexible control/fault  
diagnosis • Meets latest EPC standards: Cyclone BFC 28-60: 0.902  
• Utilises premix Low-NOx burner BFC 80/100 • Patented Cyclone  
burner BFC28-60 • All models suitable for natural or LP gas  
• Programmable for legionella purge cycle • Scale formation is  
reduced through the improved design and location of the heat  
exchanger • Cyclone BFC 80/100: comes as standard with powered  
anodes to reduce maintenance requirements • Remote control  
connection • Voltage-free contact for general fault indication  
• Optional ancillaries: Unvented kits • Destratification pump kit  
• Powered anodes  
Meets  
EPC  
standards  
Innovation has a name.  
Cyclone BFC  
Technical specifications  
Gas data natural gas 2H (G20)  
Input*  
kW  
32.1  
30.5  
20  
8.5  
3.1  
4.90  
70  
56.8  
34.5  
32.7  
20  
8.5  
3.3  
5.10  
50  
61.1  
52.6  
48.8  
20  
8.5  
5.0  
7.00  
75  
85.4  
63.2  
59.6  
20  
11.5  
6.0  
7.10  
75  
101.4  
86.6  
81.9  
20  
7.0  
8.3  
6.30  
50  
141.9  
105.5  
99.8  
20  
Output  
kW  
Inlet pressure  
mbar  
mbar  
m3/h  
mm  
°C  
Burner pressure  
Gas consumption**  
Diameter main orifice  
Max. flue gas temperature  
Flue gas discharge  
6.0  
10.1  
6.80  
50  
kg/h  
164.3  
Gas data butane 3+ (G30)  
Input*  
Output  
Inlet pressure  
Burner pressure  
Gas consumption**  
Diameter main orifice  
Max. flue gas temperature  
Flue gas discharge  
kW  
kW  
30.7  
29.8  
30  
30  
2.2  
2.50  
70  
60.0  
32.8  
31.8  
30  
30  
2.4  
2.60  
50  
62.2  
50.6  
48.1  
30  
30  
3.7  
3.40  
75  
86.0  
59.4  
57.4  
30  
30  
4.3  
3.80  
75  
101.9  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
mbar  
mbar  
kg/h  
mm  
°C  
kg/h  
Gas data propane 3+ (G31)  
Input*  
Output  
Inlet pressure  
Burner pressure  
Gas consumption**  
Diameter main orifice  
Max. flue gas temperature  
Flue gas discharge  
***  
***  
***  
***  
***  
***  
***  
***  
***  
***  
***  
***  
***  
***  
***  
***  
kW  
kW  
29.0  
28.1  
37  
37  
2.1  
2.50  
70  
54.3  
30.9  
29.8  
37  
37  
2.2  
2.60  
50  
56.5  
50.3  
47.7  
37  
37  
3.6  
3.40  
75  
85.1  
59.1  
56.9  
37  
37  
4.2  
3.80  
75  
101.0  
84.8  
81.9  
37  
13.0  
6.1  
4.70  
50  
142.1  
103.3  
99.8  
37  
13.0  
7.4  
5.10  
50  
176.4  
mbar  
mbar  
kg/h  
mm  
°C  
kg/h  
Draw-off capacity  
Storage capacity  
Max. temperature setting  
l
°C  
217  
80  
368  
80  
368  
80  
368  
80  
460  
80  
460  
80  
T
= 10ºC / T = 70ºC  
set  
cold  
30 min. T=44°C  
60 min. T=44°C  
90 min. T=44°C  
120 min. T=44°C  
Continuous T=44°C  
Heating-up time T=44°C  
30 min. T=50°C  
60 min. T=50°C  
90 min. T=50°C  
120 min. T=50°C  
Continuous T=50°C  
Heating-up time T=50°C  
30 min. T=55°C  
60 min. T=55°C  
90 min. T=55°C  
120 min. T=55°C  
Continuous T=55°C  
Heating-up time T=55°C  
l
l
l
l
505  
802  
1100  
1398  
595  
22  
444  
707  
968  
1230  
524  
25  
404  
642  
880  
1118  
476  
27  
689  
1008  
1327  
1646  
638  
35  
606  
887  
1168  
1449  
562  
39  
551  
806  
1062  
1317  
511  
43  
831  
1308  
1785  
2262  
954  
23  
731  
1151  
1571  
1991  
840  
26  
665  
1046  
1418  
1810  
763  
925  
1507  
2089  
2671  
1164  
19  
1222  
2023  
2823  
3623  
1601  
17  
1076  
1780  
2484  
3189  
1409  
20  
1379  
2354  
3329  
4304  
1950  
14  
1214  
2072  
2929  
3787  
1716  
16  
1109  
1883  
2663  
3443  
1560  
18  
l/h  
min.  
l
l
l
l
l/h  
min.  
l
l
l
l
814  
1326  
1839  
2351  
1024  
22  
740  
978  
1206  
1671  
2137  
931  
1618  
2258  
2899  
1281  
22  
l/h  
min.  
29  
24  
Electrical data  
Power consumption  
Power supply  
W
VAC/Hz  
275  
275  
275  
275  
625  
710  
230 (-15/+10%). 50 (+/-1Hz)  
General  
Fan rotational speed at ignition  
Working speed of fan  
Pressure differential  
Diameter of air restrictor  
Anodes  
r.p.m.  
r.p.m.  
Pa  
mm  
-
4500  
5000  
635/605  
23  
4500  
5400  
855/825  
23  
4500  
6000  
885/855  
4500  
6660  
1085/1055  
2790  
5100  
1005/975  
36  
3120  
5700  
1145/1115  
28  
4
29  
4
38  
2
4
4
2
Maximum working pressure  
bar  
8
Shipping data  
Weight empty  
kg  
kg  
kg  
mm  
mm  
mm  
177  
394  
197  
790  
1550  
950  
214  
582  
234  
790  
2080  
950  
214  
582  
234  
790  
2080  
950  
214  
582  
234  
790  
2080  
950  
480  
940  
491  
920  
2060  
1020  
480  
940  
491  
920  
2060  
1020  
Maximum weight  
Weight incl. packaging  
Width packaging  
Height packaging  
Depth packaging  
Cyclone BFC  
Dimensions  
BFC 28-60  
A
C
D
E
1390  
-
705  
-
-
1910  
-
705  
-
-
1910  
-
705  
-
-
1910  
-
705  
-
-
2060  
530  
850  
1000  
900  
2060  
530  
850  
1000  
900  
F
G
H
80/125 100/150 100/150 100/150 130/200 130/200  
1365  
1905  
265  
375  
1800  
160  
1910  
205  
175  
75  
1905  
265  
375  
1800  
160  
1910  
205  
175  
75  
1905  
265  
375  
1800  
160  
1910  
205  
175  
75  
2015  
310  
440  
1855  
225  
2060  
205  
2015  
310  
440  
1855  
225  
2060  
205  
Hx 265  
Hy 375  
K
M
N
Ny 205  
P
R
S
1270  
170  
1390  
170  
85  
290  
225  
290  
225  
900  
1410  
145  
1410  
145  
1410  
145  
1425  
240  
1425  
240  
W 125  
1
2
3
4
5
6
7
Cold water (external)  
Hot water (external)  
Gas control (internal)  
Tank drain valve (internal)  
T&P valve (internal)  
R11/2  
R11/2  
Rp3/4  
3/4  
1-11.5 NPT  
95x70  
Cleaning and inspection opening  
Condensation drainage (internal)  
Ø40 (BFC 28)  
Rp 1 (BFC 30-100)  
Dimensions in mm. All Cyclone BFC water heaters receive a  
three years warranty on the tank and one year on parts.  
BFC 80-100  
Cyclone BFC  
Installation diagrams  
Vented  
1
3
4
5
6
9
Pressure reducing valve  
T&P valve  
Stop valve  
Non-return valve  
Circulation pump  
Drain valve  
10 Gas cock  
11 Isolating valve  
12 Temperature gauge  
13 Condense drain  
14 Hot water outlets  
15 Expansion relief valve  
16 Expansion vessel  
17 Three way valve  
18 Water tank  
19 Float valve  
A
B
C
D
E
Cold water  
Hot water  
Return circulation  
Gas supply  
Overflow pipe  
Expansion vent pipe  
H
A.O. Smith unvented system kits utilise combination valves.  
Further installation and connection details can be found in  
the Installation & Commissioning Manual.  
Unvented  
Cyclone BFC  
Electrical diagram BFC 28-60  
TERMINAL STRIP CONNECTIONS  
CONTROLLER CONNECTIONS  
J1 Connector for display to controller  
J2 Connector for power supply to  
controller  
J19 Connector for extra error signal  
J20 Connector for gas control  
J21 Connector for program-  
controlled pump  
Earth  
N
Neutral  
L1 Phase input of controller  
L2 Phase input of isolating  
transformer (primary side)  
L3 Phase output of isolating  
transformer (secondary side)  
L4 Phase input of program-controlled  
pump  
J24 Connector for fan  
JP2 Connector for ionisation rod and  
glow igniter  
L5 Phase input of continuous pump  
JP3 Connector for temperature  
sensor T2  
COMPONENTS  
A
B
C
D
E
Controller  
Ionisation rod  
Glow igniter  
Gas control  
JP4 Connector for dummy  
JP5 Connector for temperature  
sensor T1  
JP6 Connector for selection resistor  
and pressure switch  
Burner earth connection  
Extra ON mode switch  
Continuous pump  
Program-controlled pump  
Extra error signal  
Isolating transformer  
Double-pole mains switch  
ON/OFF switch control  
Display/Flat cable  
Fan  
Temperature sensor  
(T2 - bottom of tank)  
Dummy  
Temperature sensor  
(T1 - top of tank)  
Selection resistor  
Pressure switch  
F
JP8 Connector for extra  
ON mode switch  
G
H
J
K
L
M
N
O
P
F1 Fuse  
F2 Fuse  
Colour cables  
1 =brown  
2 =blue  
3 =yellow/green  
4 =black  
5 =white (flat cable)  
6 =grey/beige  
Q
R
S
T
Cyclone BFC  
Electrical diagram BFC 80-100  
TERMINAL STRIP CONNECTIONS  
CONTROLLER CONNECTIONS  
J2 Connector for power supply  
to controller  
J19 Connector for external error-signal  
J20 Connector for gas-control  
J21 Connector for program  
controlled pump  
J36 Connector for display  
to controller  
J39 Connector for fan controlled signal  
JP2 Connector for ionisation rod and  
glow ignitor  
Earth  
N
L
Neutral  
Phase input of controller  
L1 Phase output of isolating  
transformer ( secundary side)  
L2 Phase input of isolating  
transformer ( primary side)  
L3 Phase input of program-  
controlled pump  
L4 Phase input of frequency  
controller  
L5 Phase input of continuous pump  
JP3 Connector for temperature  
sensor T2  
COMPONENTS  
JP4 Connector for dummy  
JP5 Connector for temperature  
sensor T1  
JP6 Connector for selection resistor,  
pressure switch and anode  
signaling  
A
B
C
D
E
Controller  
Ionisation rod  
Glow ignitor  
Gas control  
Burner earth connection  
External ON-mode switch  
Program-controlled pump  
External error-signal  
Isolating transformer  
Double-pole mains switch  
Controller 0/1 switch  
Display/Flat cable  
Fan  
F
JP8 Connector for extra  
ON-mode switch  
G
H
J
K
L
M
N
O
F1 Fuse  
F3 Fuse  
Temperaturesensor  
(T2-bottom of tank)  
Dummy  
P
Q
Temperaturesensor  
(T1-top of tank)  
Colour cables  
1 =brown  
2 =blue  
R
S
Selection resistor  
Pressure switch  
T
Potentiostat  
3 =yellow/green  
4 =black  
5 =white (flat cable)  
6 =grey/beige  
7 = red  
U
V
W
X
Y
Frequency controller  
Argus-link interface  
Electric anodes  
Signaling for electric anodes  
Mains choke and EMC filter  
8 =green  
Flue systems Cyclone BFC  
A Cyclone BFC water heater should be installed according  
category B23, C13, C33, C43 or C53*.  
Installation options  
C13  
Concentric  
Diameter (mm)  
Max. length (m)  
Max. 45/90° bends  
80/125  
100/150 100/150 100/150 130/200 130/200  
40  
7
40  
7
40  
7
15  
4
15  
3
15  
3
B23  
Parallel (standard diameter)  
Diameter (mm)  
Max. length (m)  
80  
25  
100  
80  
100  
45  
100  
25  
130  
115  
2,4  
130  
60  
L
L
/bend 90° (m) 3,9  
equivalent  
/bend 45º (m) 1,1  
equivalent  
4,6  
1,2  
4,6  
1,2  
4,6  
1,2  
2,4  
1,4  
1,4  
Parallel (larger diameter for more length)  
Diameter (mm)  
Max. length (m)  
100  
100  
130  
100  
2,4  
130  
100  
2,4  
130  
100  
2,4  
150  
100  
2,6  
150  
100  
2,6  
C33  
L
L
/bend 90º (m) 4,6  
equivalent  
equivalent  
/bend 45º (m) 1,2  
1,4  
1,4  
1,4  
1,6  
1,6  
*
All Cyclone BFC are also approved for installations where the unit is supplied  
without venting materials (C63).  
Concentric flues  
It is not permitted to use more than the specified number of  
bends, even when the duct is shorter than the maximum  
length. A 45° bend is equivalent to a 90° bend.  
Parallel flues  
- The maximum permissible length should be reduced by the  
equivalent length of each bend. (Note: for a parallel installation  
this means that 3 changes in direction amount to 6 bends  
(3 in the supply duct and 3 in the flue).  
- The maximum length also applies if a parallel installation has  
different supply and flue duct lengths (B23, C53).  
- Combined flues (C43) shall be fitted with a condensate drain.  
C53  
C43  
Note: horizontal flue runs must be installed with a fall of at least  
5 mm per metre.  
Flue systems Cyclone BFC  
Minimum space requirements  
BFC 28-60  
Ø80/125 Ø100/150 Ø100/150 Ø100/150 Ø130/200 Ø130/200  
Minimal space for wall duct (mm)  
V
550  
550  
550  
550  
640  
640  
W
X
725  
790  
790  
790  
940  
940  
1535  
1460  
1010  
2075  
1480  
1030  
2075  
1480  
1030  
2075  
1480  
1030  
2230  
1620  
1170  
2230  
1620  
1170  
Y
Y *  
Minimal space for roof duct (mm)  
V
1305  
680  
1500  
1035  
3325  
2375  
1415  
465  
1500  
1035  
3325  
2375  
1415  
465  
1500  
1035  
3325  
2375  
1415  
465  
1730  
1120  
3620  
2670  
1560  
610  
1730  
1120  
3620  
2670  
1560  
610  
W
X
2965  
2015  
1575  
625  
BFC 80-100  
X **  
Y
Y **  
For the parts numbers of components and flue gas ducts, etc.  
please refer to the “Maintenance and accessories” chapter.  
*
Distance without concentric pipe between bend and wall duct.  
** Distance without concentric pipe between appliance and roof duct.  

AO Smith Water Heater ACGSS02407 User Guide
AO Smith Water Heater DVE 120 User Manual
AO Smith Water Heater GCV 40 200201 User Manual
AO Smith Water Heater GP 6 50YPC T 100 User Manual
AO Smith Water Heater KENSE 80 User Manual