AO Smith Boiler VWT 1000 User Guide

Commercial Gas Boilers  
VWT-500  
through  
VWT-1000  
TOTAL HOT WATER SUPPLY SYSTEM USING VFBOILERS  
With Ac-U-Temp, A. O. Smith makes it as easy as possible to install a complete packaged hot  
water supply system, combining high-efficiency VFboilers with storage tanks up to 10,000  
gallons. Each Ac-U-Temp system is custom-made to your specifications for each application  
and shipped fully assembled, pre-piped and pre-wired. All the installer has to do is make the  
flue, gas, electrical and water connections, so installations are easy.  
Consult your A. O. Smith representative for more information  
on the wide range of available boiler/storage tank combinations  
using the Ac-U-Temp system.  
VF MODULATING BOILERS  
UP TO 88% THERMAL EFFICIENCY  
• A. O. Smith’s most efficient hot water supply boilers  
• Available inputs: 500,000, 750,000, 1,000,000 BTUs  
• Flexible conventional-vent or sealed-combustion  
direct-vent options  
• For complete information on VF Hot Water Supply  
Boilers, consult VF Specification Sheet  
GLASS-LINED STORAGE TANKS  
• Standard capacities up to 1,000 gallons  
• Custom tanks available up to 10,000 gallons  
• Standard tanks are factory jacketed and insulated –  
bare uninsulated tanks also available  
• Optional cement or epoxy-lined tanks available  
• For complete information on standard and optional  
tanks, consult tank Specification Sheet  
MULTIPLE BOILER SYSTEMS  
• Ac-U-Temp systems can be designed with multiple  
boilers to provide 50% to 100% back-up  
• Multi-boiler systems can be sequenced to meet  
changing system demands  
• Sequenced multi-boiler systems with small storage  
tanks are ideal for applications with relatively constant  
hot water demands  
• Optional sequenced control panel available  
MULTIPLE TANK SYSTEMS  
• Ac-U-Temp systems can be designed with multiple  
tanks for applications with low ceiling heights or other  
unique installation challenges  
Page 1 of 4  
ACMSS00507  
Download from Www.Somanuals.com. All Manuals Search And Download.  
July 2007R  
BOILER DATA  
DIMENSIONS  
INCHES  
OR  
CM  
MODEL  
NUMBER  
LENGTH  
(C2)  
WIDTH  
(C1)  
HEIGHT  
(D)  
INLET SIZE GAS INLET  
Inches  
CM  
Inches  
CM  
Inches  
CM  
30  
76.2  
30  
76.2  
30  
30  
76.2  
30  
76.2  
30  
60  
152.4  
66  
167.6  
75  
2
5.1  
2
5.1  
2
1
2.5  
1
2.5  
1
VW-500  
VW-750  
VW-1000  
76.2  
76.2  
190.5  
5.1  
2.5  
VERTICAL STORAGE VESSEL DATA  
DIMENSIONS  
INLET  
HEIGHT (B2)  
INCHES  
MODEL  
OR  
HEIGHT  
(A)  
WIDTH  
(B1)  
NUMBER  
INLET SIZE OUTLET SIZE  
CM  
Inches  
CM  
Inches  
CM  
Inches  
CM  
Inches  
CM  
Inches  
CM  
Inches  
CM  
Inches  
CM  
Inches  
CM  
66-1/4  
168.3  
66  
167.6  
88  
223.5  
84  
213.4  
96  
243.8  
99  
251.5  
105  
233.7  
101  
256.5  
86  
28  
71.1  
28  
76.2  
30  
76.2  
36  
91.4  
36  
91.4  
42  
106.7  
42  
106.7  
48  
121.9  
54  
15  
38.1  
15  
167.6  
19-1/2  
49.5  
21  
2
5.1  
2
2
5.1  
2
AJ-80A  
AJV-120A  
AJV-140A  
AJV-200A  
AJV-250A  
AJV-350A  
AJV-400A  
AJV-500TA  
AJV-500A  
AJV-750A  
AJV-1000A  
5.1  
2-1/2  
6.4  
2-1/2  
6.4  
2-1/2  
6.4  
2-1/2  
6.4  
2-1/2  
6.4  
3
6.4  
3
6.4  
3
6.4  
3
6.4  
2.5  
2-1/2  
6.4  
2-1/2  
6.4  
2-1/2  
6.4  
2-1/2  
6.4  
2-1/2  
6.4  
3
6.4  
3
6.4  
3
6.4  
3
6.4  
53.3  
21  
53.3  
22-1/2  
57.2  
22-1/2  
57.2  
24  
61  
Inches  
CM  
Inches  
CM  
Inches  
CM  
25-1/5  
64.8  
24-1/2  
62.2  
25-1/2  
64.8  
218.4  
118  
299.7  
150  
137.2  
54  
137.2  
54  
381  
137.2  
HORIZONTAL STORAGE VESSEL DATA  
DIMENSIONS  
INCHES  
MODEL  
OR  
LENGTH OUTLET DIM  
WIDTH  
(B1)  
HEIGHT  
(B2)  
INLET  
HEIGHT (B3)  
INLET  
SIZE  
OUTLET  
SIZE  
NUMBER  
CM  
(A1)  
(A2)  
Inches  
CM  
77  
195.6  
93  
59  
36  
91.4  
42  
41  
104.1  
47  
11  
27.9  
14  
2-1/2  
6.4  
2-1/2  
6.4  
3
2-1/2  
6.4  
2-1/2  
6.4  
3
AJH-200  
AJH-350  
149.9  
72-1/2  
184.2  
72-1/2  
184.2  
73  
185.4  
56-1/2  
143.5  
88-1/2  
224.8  
120-1/2  
306.1  
Inches  
CM  
236.2  
99  
106.7  
42  
119.4  
47  
35.6  
14  
Inches  
CM  
Inches  
CM  
Inches  
CM  
Inches  
CM  
AJH-350  
AJH-350  
AJH-350  
AJH-350  
AJH-350  
251.5  
94  
238.8  
79  
200.7  
111  
281.9  
143  
106.7  
48  
121.9  
54  
137.2  
54  
137.2  
54  
119.4  
53  
134.6  
59  
149.9  
59  
149.9  
59  
35.6  
14  
35.6  
14  
35.6  
14  
35.6  
14  
7.6  
3
7.6  
3
7.6  
3
7.6  
3
7.6  
3
7.6  
3
7.6  
3
7.6  
3
Inches  
CM  
363.2  
137.2  
149.9  
35.6  
7.6  
7.6  
Page 2 of 4  
ACMSS00507  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Commercial Gas Boilers  
TOTAL HOT WATER SUPPLY SYSTEM USING VFBOILERS  
Configuration H  
Configuration P  
Configuration V  
The above are standard available configurations. Custom configurations designed to your specifications are available. Contact your local  
A. O. Smith Sales Representative for assistance.  
Page 3 of 4  
ACMSS00507  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Commercial Gas Boilers  
TOTAL HOT WATER SUPPLY SYSTEM USING VFBOILERS  
OTHER FEATURES:  
DUAL-ENERGY SOURCE OPTION  
ASME TEMPERATURE AND PRESSURE RELIEF  
VALVE #125  
• Storage tanks can be specified with an optional  
heat exchanger for winter heating using on-site  
hydronic heating boiler(s), switching to domestic  
hot water boiler(s) for summertime operation  
TANK TEMPERATURE SENSOR AND  
THERMOMETER  
ISOLATION VALVES (BALL VALVES)  
125 PSI TANK WORKING PRESSURE  
ALL-BRONZE CIRCULATING PUMP  
LARGE SYSTEMS SHIPPED WITH SPLIT/  
BOLT TOGETHER SKIDS FOR EASE OF  
SHIPPING AND INSTALLATION  
• Water-to-water or steam-to-water heat exchangers  
available in single-wall or double-wall design  
• Complete control packages can be factory-installed  
for “hook up and run” simplicity  
PROFESSIONAL START-UP SERVICE FURNISHED  
Assures optimum performance for each installation  
OTHER OPTIONS:  
150 AND 160 PSI TANK WORKING PRESSURES  
11˝ X 15˝ MANHOLES  
MEETS ASHRAE/IESNA 90.1-1999  
5 YEAR VF BOILER HEAT EXCHANGER WARRANTY  
5 YEAR STORAGE TANK WARRANTY  
For complete information, consult written warranty or  
contact A. O. Smith  
Tank Type (A=Skid Mounted, J=Jacketed, V=Vertical, H= Horizontal)  
SUGGESTED SPECIFICATION  
Hot Water Supply System - shall consist of A. O. SMITH Ac-U-Temp factory assembled unit Model No. __________. System  
shall be completely factory assembled and shall include the A.O. SMITH VF hot water supply boiler(s), with input  
of ____ BTU/H for (natural/propane) ____ gas and recovery capacity of _______ gph, and the A.O. SMITH glass-lined  
(cement/epoxy) hot water storage tank with ____ gallons capacity for ________ mounting (vertical-horizontal). System  
shall include properly sized circulator, inlet and outlet thermometers, tank temperature thermometer, relief valve, and tank  
temperature control. Entire system shall be rigidly mounted on welded steel skid base and shipped assembled to job site  
(Ac-U-Temp systems employing tanks too large for shipping as an assembled unit, will be shipped with the tank mounted  
on a split bolt-together skid). See VF Boiler Specification Sheet for boiler details. See A.O.Smith Storage Specification  
sheets for storage tank details.  
Hot water supply boiler(s) and storage tank(s) shall have a 5 year limited warranty against corrosion as outlined in the  
written warranty  
For Technical Information and Automated Fax Service, call 800-527-1953.  
A. O. Smith reserves the right to make product changes or improvements without prior notice.  
500 Tennessee Waltz Pkwy, Ashland City, TN 37015  
Page 4 of 4  
ACMSS00507  
Download from Www.Somanuals.com. All Manuals Search And Download.  
©2007 A. O. Smith Corporation  
Printed in U.S.A.  

AO Smith Water Heater 318257 000 User Guide
AO Smith Water Heater EWS 15 User Manual
AO Smith Water Heater FPS40 User Manual
AO Smith Water Heater GNR50100 User Manual
AO Smith Water Heater Series 240 User Manual