AO Smith Water Heater BTR 151 through BTR 201 User Manual

Commercial Gas Water Heaters  
BTR-151  
through  
BTR-201  
BOOSTER MODELS  
The Master-Fit® BTR-151 and BTR-201 are designed for installation in “booster”  
applications, to supply commercial dishwashers with very high temperature water…  
usually 180ºF. A booster water heater is normally used in conjunction with a  
standard water heater water delivering hot water at a lower temperature to meet  
the non-dishwashing needs of a restaurant or other foodservice application.  
With a 32-gallon storage tank, these compact units measure only 45'' high,  
and hot and cold water connections can be made in the top, front or rear,  
for installation versatility.  
THE ELIMINATOR SELF-CLEANING SYSTEM  
• Designed to significantly reduce or eliminate buildup of lime, sand and  
other sediment inside the tank  
• Reduced sediment buildup helps Master-Fit water heaters maintain their  
rated energy-efficiency and reduce water heating costs  
• Self-cleaning system also helps prolong tank life  
BUILT-IN INDUCED DRAFT BLOWER  
• Produces power-induced draft of makeup air prior to burner ignition  
• Provides more efficient control of heat through the flue collector  
• No draft hood or barometric damper required  
RATED AS CATEGORY 1 APPLIANCE  
• Can be commonly vented with other Category 1 appliances, using standard  
metal type “B” vent  
PERMAGLAS® ULTRA COAT GLASS LINING  
• Exclusive process provides superior protection against corrosion  
• CoreGard anode rods with stainless steel core provide additional  
corrosion protection  
THREE WATER CONNECTION OPTIONS  
• Hot and cold water connections can be made through top, front or rear of water heater  
• The Eliminator self-cleaning device operates when cold water is connected  
through front  
INTERMITTENT ELECTRONIC IGNITION  
• Eliminates standing pilot  
• Includes power ON/OFF switch  
• Provides flame failure response in less than one second  
FACTORY-INSTALLED TEMPERATURE & PRESSURE RELIEF VALVE  
MAXIMUM HYDROSTATIC WORKING PRESSURE 160 PSI  
80% THERMAL EFFICIENCY  
CODES AND STANDARDS  
• Design-certified by UL (Underwriters Laboratories), according to  
ANSZ21.10.3-CSA4.3 standards governing storage-type water heaters  
• Meets ASHRAE/IESNA 90.1-1999  
• Optional ASME construction available  
WARRANTY  
• Three-year limited warranty against tank leaks  
• For complete warranty information, consult written warranty shipped  
with water heater, or contact A.O. Smith Water Products Company  
ACGSS00705  
June2007R  
Commercial Gas Water Heaters  
1" NPI RELIEF  
1 1/2" NPI  
OUTLET  
H
15.2cm  
VALVE OPENING  
BOOSTER MODELS  
CAPACITY, INPUT AND OUTPUT  
RECOVERYGALLONS or LITRES  
PER HOUR AT DEGREE RISE  
BTU  
MODEL INPUT  
NUMBER PER  
HOUR  
Gallons  
or  
FIRST GPH  
HOUR or  
RATING LPH  
A
TANK  
SIZE  
B
40°F 60°F 80°F 100°F 140°F  
22°C 33°C 44°C 56°C 78°C  
Litres  
D
C
E
U.S.Gallons  
32  
167  
GPH 364 242 182 145 104  
BTR-151 150,000  
BTR-201 199,000  
G
F
Litres  
U.S.Gallons  
Litres  
121.1 632.1  
32 216  
121.1 817.6  
LPH 1377.7 916 688.9 548.8 393.6  
GPH 485 322 241 194 139  
LPH 1835.7 1218.8 912.2 734.3 526.1  
1 1/2" NPI  
INLET  
1.5  
3.8cm  
CLEARANCE  
DIMENSIONS AND WEIGHT  
APPROX.  
DIMENSIONS  
MODEL  
NUMBER  
GAS  
CONN.  
WATER SHIPPING  
CONN.  
WEIGHT  
(LBS.)  
A
B
C
D
E
F
G
H
inches  
cm  
45  
40  
27-3/4 32-1/4 15-3/4  
5
6-1/2  
6
3/4  
-
1-1/2  
-
460  
BTR-151  
and  
BTR-201  
114.3  
101.6  
70.5  
81.9  
40  
12.7  
16.5  
15.2  
181.8  
SUGGESTED SPECIFICATION  
Gas booster water heater(s) shall be A.O. Smith Master-Fit, Model Number ___________________, with a 32-gallon storage  
capacity, an input rate of __________________ BTU/HR, _________________ gas, and a recovery rate of ________ gallons  
per hour at a ________ degree Fahrenheit temperature rise, and a maximum hydrostatic working pressure of 160 psi.  
Unit(s) shall have a fan-assisted combustion system, providing a power-induced draft of makeup air prior to burner ignition.  
Unit(s) shall be equipped with intermittent electronic ignition with power on/off switch, which shall provide flame failure  
response in less than one second. The burner for the unit(s) shall be easily removable. Unit(s) shall be equipped with a  
factory-installed temperature and pressure relief valve, and a 2-3/4'' x 3-3/4'' tank inspection port.  
The water heater tank shall be glasslined and protected against premature failure in the following ways:  
1. Against electrolytic corrosion by multiple, factory-installed anode rods  
2. Against failure due to overheating caused by the buildup of scale, film and other sediment by a self-cleaning device,  
positioned inside the tank so that it directs the flow of inlet water in such a way that microscopic particles of precipitated  
solids shall be kept in suspension and exhausted from the water heater on that or successive hot water draws.  
Unit(s) shall meet or exceed ASHRAE/IESNA 90.1-1999, and be design certified by UL (Underwriters Laboratories), according  
to ANSZ21.10.3-CSA4.3 standards governing storage-type water heaters.  
For Technical Information and Automated Fax Service, call 800-527-1953.  
500 Tennesse Waltz Parkway, Ashland City, TN 37015  
A.O. Smith reserves the right to make product changes or improvements without prior notice.  
Printed in U.S.A.  
ACGSS00705  

AO Smith Water Heater AOSRG45900 User Manual
AO Smith Water Heater COF 455A User Manual
AO Smith Water Heater COF 700 User Manual
AO Smith Water Heater GDVS 50 User Manual
AO Smith Water Heater GPSH 4050 User Manual