AO Smith Water Heater Series 100101 User Manual

Residential Gas Water Heaters  
PROMAX® PLUS HIGH RECOVER FEATURES  
HIGHEST RECOVERIES AND FIRST HOUR RATINGS  
Capacity/input combinations up to 98 gallons/75,100 BTUs produce  
recoveries up to 81 gallons per hour, with deliverable hot water up  
to 150 gallons.  
A. O. SMITH DYNACLEAN™ DIFFUSER DIP TUBE  
Helps reduce lime and sediment buildup, maximizes hot water output. Made from long-  
lasting PEX cross-link polymer.  
GREEN CHOICE® GAS BURNER  
Patented “Eco-Friendly” design reduces NOx emissions by up to 33%, complies with  
Texas requirements for NOx emissions.  
COREGARD™ ANODE ROD  
A. O. Smith’s exclusive aluminum anode has a stainless steel core, protects tank  
against corrosion longer versus ordinary mild steel anodes.  
PUSH-BUTTON PIEZO IGNITER  
Makes lighting pilot fast and easy with one-hand push-button spark ignition.  
Standard on C3 Technology® models.  
HEAT TRAP NIPPLES*  
Factory installed on most models.  
DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE  
THICK CFC-FREE FOAM INSULATION  
Improves efficiency.  
A. O. SMITH PERMAGLAS® GLASS COATING  
Protects steel tank from rust.  
FACTORY-INSTALLED TEMPERATURE  
AND PRESSURE (T&P) RELIEF VALVE  
Top-mounted T&P Valve available as option on C3 Technology models.  
CODE COMPLIANCE: UBC, CEC, SBCC, CABO, HUD,  
BOCA NATIONAL CODES, ASHRAE/IES 90.1-1999 AND  
2004 NAECA  
DESIGN-CERTIFIED BY CSA INTERNATIONAL  
According to ANS Z21.10.1* standards governing storage-type water heaters.  
*75 and 100 models certified to ANS Z21.10.3  
Series 100/101  
6-YEAR LIMITED TANK AND PARTS WARRANTY  
For complete information, consult written warranty or A. O. Smith Water Products  
Company.  
EQUIPPED WITH C3 TECHNOLOGY®  
See other side.  
®
Page 1 of 2  
Revised September 2008  
AOSRG45400  
Residential Gas Water Heaters  
DIMENSIONS (INCHES)  
FIRST  
HOUR  
RATING  
(GPH)  
RECOVERY  
90°F RISE  
PER HOUR  
BTU INPUT  
PER HOUR  
NATURAL†  
APPROX.  
SHIPPING  
WEIGHT  
(LBS)  
DRAFT  
HOOD  
MODEL  
NUMBER  
GALLON  
CAPACITY  
ENERGY  
FACTOR  
R
VALUE  
OUTLET  
A
B
C
D
E
F
88  
38  
48  
138  
172  
195  
215  
275  
350  
GCVT-40  
0.60  
50,000  
50,000  
65,000  
65,000  
75,100  
75,100  
16  
8
58-1/2 54-3/4 20-1/2 13-3/8  
8
8
8
8
48-7/8  
50-3/8  
54-1/8  
54-1/4  
4
4
4
4
4
4
60-7/8 56-1/2  
63-7/8 59-1/2  
20  
22  
24  
13-3/8  
15-1/2  
15-1/2  
90  
93  
48  
50  
65  
74  
51  
67  
67  
81  
GCVT-50  
GCVX-50  
GCV-65  
0.58  
0.58  
0.57  
N/A  
16  
16  
16  
10  
65  
61  
60  
57  
65  
116  
N/A  
FCG-75*  
26-1/2 14-3/4 16 50-1/4  
27-3/4 15-3/16 16 57-3/8  
68-1/2  
N/A  
98  
81  
FCG-100*  
N/A  
Recovery capacity based on actual performance tests. Water Connections – 1" on 75-gallon model, 1-1/4" on 100-gallon model, 3⁄4"on all other models.  
* Not equipped with C3 Technology. 75 and 100 gallon models have factory installed (non heat trap) nipples, 75-gallon model has 80% efficiency,  
998 BTU/hr. standby loss; 100-gallon model has 80% efficiency, 1146 BTU/hr. standby loss.  
† Propane Gas – GCVT-40: 47,000 BTU input; GCVT-50: 45,000 BTU input; GCVX-50: 55,000 BTU input; GCV-65: 62,500 BTU input.  
For 10-Year Tank and 6-Year Parts Warranty, change “G” to “X” in Model Number (example: XCVT-40), or change “F” to “P” in model number(example: PCG-75).  
The standard FVIR models are certified for installations to 7700 feet elevation. For high attitude versions of the 75 & 100-gallon models add SMR “S19”  
HOT CONNECTION  
Flammable Vapor Ignition  
ANODE ROD*  
Resistant C3 Technology®  
Water Heaters  
Corderite Combustion Containment (C3) design meets American National  
Standards Institute standards (ANS Z21.10.1) that deal with the accidental or  
unintended ignition of flammable vapors, such as those emitted by gasoline.  
COLD  
CONNECTION  
E
C
Covered by four U.S. patents, C3 Technology gas water heaters feature a sealed  
combustion chamber with air intake screen and a fireproof Corderite flame  
arrestor built into the water heater base. In addition, a thermal cutoff (TCO)  
device, integral with the thermocouple, is designed to shut off gas flow to the  
burner and pilot if poor combustion is detected.  
T&P VALVE  
If flammable vapors  
accidentally enter the  
combustion chamber,  
the Corderite flame  
arrestor is designed  
so flames burn off  
A
B
1/2" GAS  
CONNECTION  
F
the top surface and  
cannot escape down  
through the arrestor.  
D
*Location for optional top-mounted  
T&P Valve if ordered from factory.  
A. Easy-to-light  
B. View port for easy  
burner inspection  
inside sealed  
(C3 models only)  
piezo igniter  
combustion chamber  
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.  
Revised September 2008  
Page 2 of 2  
AOSRG45400  

AO Smith Water Heater ADMP 80 User Manual
AO Smith Water Heater ADMR 80 User Manual
AO Smith Water Heater DEL User Manual
AO Smith Water Heater IT 500 User Manual
AO Smith Water Heater TJV 200M User Manual