AO Smith Water Heater TJH User Manual

Commercial Storage Tanks  
CUSTOM-LINE FACTORY JACKETED AND  
INSULATED STORAGE TANKS  
MODELS  
TJV TJH  
AND  
Large volume tanks are designed for storing potable water. Fitting locations  
of these custom-line tanks match the needs of normal installations plus those  
®
for the A. O. Smith Cer-Temp 80 and Shure-Temp systems.  
FEATURES  
STANDARD SIZES FROM 140 TO 1,000 GALLONS A. O. Smith stocks vertical  
factory jacketed and insulated tanks from 140 gallons up to 1,000 gallons for  
fast delivery and retrofit applications. All stock tanks are glass-lined with  
standard tank openings as shown on following pages. For custom or larger  
capacities, see our custom line tanks or consult your factory representatives.  
ASME CODE CONSTRUCTION - All tanks are constructed to the requirements of  
the ASME. ASME code tanks are available in 100, 125, 150 and 160 psi working pressures  
(125 psi working pressure - standard). Consult factory for ASME code tanks with greater  
or lesser working pressures, with special configurations or materials.  
INSULATION - Entire tank is surrounded with high density fiber  
glass insulation to reduce costly heat loss; non-sagging and  
vermin-proof. To meet ASHRAE 90.1 (current standard) depth of  
insulation cavity requires use of remote bulb-type tank  
temperature control and thermometer.  
CABINET - Heavy gauge steel with high quality powder coat paint  
provides additional insulating qualities for greater energy savings.  
LININGS AND COATINGS - Each lining and coating has  
particular capabilities and limitations. Please consult the  
factory for recommendations on the uses of linings for specific applications.  
Thorough investigation on the service life of steel tanks with protective coatings  
or linings has led to the recommendations of the following linings:  
Glass-lined (Standard) - These are normally stocked tanks for water storage up to 180 F,  
with glass lining to prevent corrosion and addition of rust to water. The glass lining was  
developed over many years of ceramic research for a wide variety of conditions.  
Cement - A special formulation of cement provides excellent corrosion protection. Available  
on 200 gallon and larger sizes. A manhole or handhole is included for application of cement lining.  
Epoxy - The application of specially formulated epoxy makes this lining suitable for cold or hot  
water storage. A manhole or handhole is included for application of epoxy lining. Available on 200  
gallon and larger sizes.  
CATHODIC PROTECTION - Glass-lined, cement and epoxy tanks are furnished with  
anodes designed for maximum protection.  
OPTIONAL  
ACCESSORIES - Tanks will be supplied with the fittings located  
as indicated on the drawings unless specified otherwise. A  
manhole or handhole is included on cement or epoxy tanks.  
A manhole or handhole is optional on glass-lined tanks.  
CRN  
Page 1 of 4  
Revised May 2008  
AOSTT35200  
Commercial Storage Tanks  
STORAGE TANK SELECTION  
TJV-140 THRU TJV-1000  
FIGURE 1.  
NOTE: Inspection openings, i.e., handholes and manholes, are optional and are to be included with glass lined tanks  
only when specified. Tanks so equipped are f.o.b. Seattle.  
Other tanks to 66” diameter and 3500 gallon are available on special order.  
All openings Female Pipe Thread except as noted.  
“F” opening Male Pipe Thread.  
MODEL AND  
GALLON  
CAPACITY  
TJV-140  
TJV-200  
TJV-250  
TJV-350  
TJV-400  
TJVT-500  
TJV-500  
TJV-750  
TJV-1000  
A
B
C
D
51  
E
F
G
2 1/2  
2 1/2  
2 1/2  
2 1/2  
2 1/2  
3
H
87  
30  
36  
36  
42  
42  
48  
54  
54  
54  
21 1/2  
22  
8
1 1/2  
1 1/2  
1 1/2  
1 1/2  
1 1/2  
1 1/2  
1 1/2  
1 1/2  
1 1/2  
6 3/8  
83  
45  
10  
10  
14  
14  
16  
18  
18  
18  
7 3/4  
93  
22  
58  
7 3/4  
97  
24 1/2  
24 1/2  
27  
54  
9 1/2  
105  
100  
84  
61  
9 1/2  
52  
11 5/16  
12 3/4  
12 3/4  
12 3/4  
27 3/4  
27 3/4  
27 3/4  
33 1/4  
65 1/2  
97 1/2  
3
116  
150  
3
3
Page 2 of 4  
AOSTT35200  
Commercial Storage Tanks  
STORAGE TANK SELECTION  
TJH-200 THRU TJH-1000  
FIGURE 2.  
NOTE: Inspection openings, i.e., handholes and manholes, are optional and are to be included with glass lined tanks  
only when specified. Tanks so equipped are f.o.b. Seattle.  
Other tanks to 66” diameter and 3500 gallon are available on special order.  
All openings Female Pipe Thread except as noted.  
MODEL AND  
GALLON  
CAPACITY  
TJH-200  
TJH-350  
TJH-400  
TJHT-500  
TJH-500  
TJH-750  
TJH-1000  
A
B
C
D
E
2 1/2  
2 1/2  
2 1/2  
3
F
G
H
16  
41  
47  
47  
53  
59  
59  
59  
36  
42  
42  
48  
54  
54  
54  
77  
16  
11  
10  
10  
11  
12  
12  
11  
23  
26  
26  
29  
32  
32  
32  
93  
17 1/2  
17 1/2  
21  
22 1/2  
26  
99  
94  
19 1/2  
11  
79  
22 3/4  
22 3/4  
22 3/4  
3
111  
143  
3
27  
3
43  
OPTIONAL  
Handle or 11” x 16” manholes  
Additional openings  
Page 3 of 4  
AOSTT35200  
Commercial Storage Tanks  
LIMITED WARRANTY OUTLINES  
GLASS-LINED, CEMENT, EPOXY: If the tank should leak anytime  
during the first five years, under the terms of the warranty,  
A. O. Smith will repair or replace the tank;  
installation, laborand handling extra.  
BLACK STEEL: If the tank should leak on installation, under the  
terms of the warranty, A. O. Smith will repair or replace the tank;  
installation, labor and handling extra.  
NOTE: THIS OUTLINE IS NOT A WARRANTY. For complete  
information, consult the written warranty or A. O. Smith Water  
Products Company.Warranty does not apply to product installed  
outside of theUnited States of America or its territorial possessions  
and Canada.  
SUGGESTED SPECIFICATION  
SAMPLE SPECIFICATION FOR CUSTOM-LINE STORAGE TANKS  
When jacketed or insulated these models meet or exceed the thermal efficiency and standby loss requirements of ASHRAE 90.1 (current standard).  
ASME storage tank to be A. O. Smith Custom-Line model ______________. Capacity to be ___________gallons with a diameter of _______ inches. Tank(s) shall be constructed and  
stamped according to ASME specifications for __________ psi working pressure. Manhole (11 x 15), handhole (4x6) or inspection openings (2-2˝) shall be installed in accordance with  
ASME code requirements and manufacturer(s) standard practice. Tank to be constructed of (carbon steel) _________. Lining shall be (glass, epoxy, cement) ______________. Tank(s) lined  
with (glass, cement, epoxy) _____________lining shall be equipped with the number and size of magnesium anode rod(s) sufficient to provide adequate protection for the tank lining.  
Tank shall be (vertical, horizontal) _______________ design and provided with (four) ___________ (angle iron legs, threaded leg socket(s)) _____________ ring base, ___________ saddles.  
SAMPLE SPECIFICATION FOR TANK HEATERS  
Tank heaters shall be Model No. ____________ 3/4˝ OD 20 gauge copper “U” tubes. Heater to have ________ square feet of heating surface to heat ____________ gallons per hour from  
_____________ degrees F to ____________ degrees F with heating media of ____________psi steam (or _________ degrees F boiler water). The element shall be constructed so that the  
entire section can be removed from the tank for cleaning and inspection.  
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.  
Revised May 2008  
Page 4 of 4  
AOSTT35200  

AO Smith Water Heater 186965 001 User Manual
AO Smith Water Heater 318257 000 User Guide
AO Smith Water Heater BTI 120 thru 400A ASME (A) User Manual
AO Smith Water Heater EES 52 User Manual
AO Smith Water Heater LBLW 700 User Manual